FTTC (Fibre-to-the-Curb) Test Methods & Topology

nbn™ FTTC (Fibre-to-the-Curb) Test Methods and Topology

We are here to assist you in understanding the nbn™ FTTC (Fibre-to-the-Curb) Testing requirements, providing specialised Test Equipment, Safety equipment, and Tools to Install and Maintain the nbn™ FTTC Fibre and Copper infrastructure and Network

NBN Logo

TMG has supplied over million+ of solutions to NBN Telecommunication Contractors for the Installation and Maintenance of Telstra/nbn™ Copper Telephone lines, ADSL & VDSL servicesFTTP (Fibre-to-the-Premises), FTTB (Fibre-to-the-Basement), FTTN (Fibre-to-the-Node), and FTTC (Fibre-to-the-Curb)

Page Contents

Breakout Joint Location (BJL)
Located in the Local Fibre Network (LFN)
BJL Image
Flexible Joint Location (FJL)
FJL Image
Distribution Joint Location (DJL)
Located in the Distribution Fibre Network (DFN)
DJL Image

When installing a new optical network it's imperative that a "baseline record" of optical link quality is recorded measuring optical loss characteristics of all links, and optical power levels. Creating a "baseline" results assist in maintaining, and troubleshooting issues that may arise after end users are connected to the network.

In nbn™'s Distribution Fibre Network (DFN) and Local Fibre Network (LFN), Uni-directional testing is performed using an Optical Time Domain Reflectometer (OTDR) to characterise the optical link at both 1310nm and 1625nm wavelengths.

An OTDR sends thousands of pulses of light into a fibre at these wavelengths to create a Trace. This trace shows "events" in optical cable, relating to optical length, splice loss, and "macro bending".

So why test at both 1310nm and 1625nm wavelengths?
By comparing the Trace of the 1310nm and 1625nm this highlights macro bending. Macrobend loss refers to losses induced in bends in the fibre predominately caused when manipulating the physical fibre inside splice closures - Breakout Joint Location (BJL), Flexible Joint Location (FJL) and Distribution Joint Location (DJL).

For more detailed information, we would recommend reading "Macrobend Detection Using an OTDR"

VIAVI LogoVIAVI MTS-4000 v2
VIAVI MTS-4000 Tri-band OTDR

The VIAVI MTS-4000 Tri-band OTDR includes 1310nm, 1550nm & 1625nm wavelengths to meet both NBN and Telstra OTDR fibre testing requirements.

Smart Link Mapper

The VIAVI Smart Link Mapper (SLM) comes as standard on the all VIAVI OTDRs and provides a block diagram overview of the trace. This excellent function helps the user breakdown the trace with icons for Splitters, connectors and bends.

The VIAVI MTS-2000 or MTS-4000 is the only OTDR currently on the market that will display the trace and SLM view on the screen at the same time.

Smart Assistant

The OTDR settings need to be changed depending on where you are testing on the Distribution or Local Fibre Network. Smart Assistant allows the user to select the section they are working on and will automatically configure the OTDR to the NBN documents.

Testing Through Splitters

The NBN Tester Architecture 3 Network now comprises of Splitters which are housed in the FJL, BJL or the SMP. These splitters can be problematic for taking OTDR traces. If the OTDR is only designed to test from point to point then you will have errors with the results given from the OTDR.

The Viavi MTS-2000 and MTS-4000 can be configured to test through the splitters allowing the user to test from the DPU all the way back to the exchange if required.

Launch Leads - What are they and why are they used?

Launch leads are an essential accessory to be used with the OTDR when testing a Fibre Network.

The launch lead places the Fibre under test far enough from the connector of the OTDR to prevent any errors caused by a possible dead zone.

For NBN a minimum of 150 metre Fibre Launch Lead must be used. and for 1,000 metres for other carriers such as Telstra.

Launch Lead image
150m Launch Lead, Singlemode

The PH Palden LL-ECO-150M is an ideal 150m long launch lead with SC/A Singlemode connectors for your NBN OTDR testing needs

VIAVI MTS-2000
VIAVI MTS-2000 Tri-band OTDR

The VIAVI MTS-2000 Tri-band OTDR includes 1310nm, 1550nm & 1625nm wavelengths to meet both NBN and Telstra OTDR fibre testing requirements.

Connecting to Optitap / Optitip ports for Testing

If you need to connect a PON meter or OTDR to the Multiport then you will need a OptiTap Adaptor. Your choice is a SCA/ HC Male and a SCA/ HC Female adapter.

OptiTap to SC/APC Adapter
OptiTap to SC/APC Adapter (FEMALE)

SC/APC to Optitap 2m Patch Lead
SC/APC to Optitap
2m Patch Lead (MALE)


Why and where are they used? 
Tests 1310 nm upstream, 1490/1550 nm downstream

VIAVI OLP-87-FTTC-BV PON Meter
VIAVI OLP-87 Image

This VIAVI OLP-87 Package is TMG's Best Value Package.   This PON Meter will test 1310nm, and 1490/1550nm downstream wavelengths.

The MAJOR benefit of the OLP-87 is that you can plug in a P5000i USB Fibre Connector Microscope (sold separately - special price when buying the OLP-87) and conduct PASS/FAIL Analysis AND save the inspection result.

Kingfisher KI6102AA-APC PON Meter
Kingfisher PON Meter

Good quality, ruggardised PON Meter.   This PON Meter will test 1310nm, and 1490/1550nm downstream wavelengths.

90% of faults in the fibre network are caused by bad connections.

This could be caused by a bad splice or a contaminated connector. As per the NBN document NBN-TE-CTO-376. It is vital; that the female and male sides of any fibre are cleaned and inspected (however new or old the fibre or connector is) before mating together or irreversible damage is caused causing more time and money to resolve.

For Fibre-to-the-Curb (FTTC), you will need to INSPECT ALL of the following;

  • the Ribbon 12F Optitip,
  • the Opti Tap Femaie / Male of the Bulkhead connector (see below), and
  • the single fibre SC/APC drop cable being terminated at the DPU.
Specialised Optitap and Optitip Inspection Probe Tips
Tip for OptiTap Inspection

VIAVI FBPT-COD-L
Tip, OptiTap Single Fibre for Fibre Inspection Probe

VIAVI LogoVIAVI USB Fibre Inspection Probe
VIAVI P5000i USB Fibre Connector Face Inspection Microscope

The P5000i makes it fast and easy to certify that every connection in your network is clear and optimized

Easily connect to an OLP-87 PON Meter, MTS-2000 or MTS-4000 OTDR, HST-3000, ONX-580, ONX-620/630 or laptop/PC via USB without the need for any additional adapters.

Splicing is required at each Splitter in the Fibre in the Local Fibre Network (LFN) and Distribution Fibre Network (DFN) parts of the Network.

Whether you are splicing Ribbon Fibre in the Distribution Fibre Network (DFN) or the de-ribbonised Fibre in the Local Fibre Network (LFN) it is important to choose a splicer with high accuracy (Low Insertion Loss) and that is quick and easy to use.


Local Fibre Network (LFN)

Single Core Alignment Splicing is required

Single Core Splicer

Sumitomo Type-72C
High Definition Single Core Aligning Fusion Splicer

To carry out splicing at the FJL or the BJL the Ribbon Fibre needs to be firstly de-ribbonised into single fibres.

Each Fibre needs to be prepared, cleaved, spliced with precision to ensure minimum loss over the splice.

The Sumitomo 72C (pictured) uses the latest in technology to line up the fibre with precision and will out the splice in seconds.


Distribution Fibre Network (DFN)

Ribbon Splicing is required

Ribbon Fusion Splicer

Sumitomo Type-71M
Mass Ribbon Fusion Splicer

The Sumitomo 71M Ribbon Splicer (pictured) is able to splice both ribbon and single core fibre.

This allows the user to Splice at the DJL using the 12 Ribbon Fibre Holder on at the FJL / BJL with the Single Fibre Holder.

Back to Top

FTTC Training and Instructional Videos

Video Series  FTTC OTDR Testing with the VIAVI (formerly JDSU) OTDRs
MTS-4000v2 OTDR Videos (FTTC/FTTP)

TMG Video Series for the VIAVI (formerly JDSU) OTDRs
This playlist currently contains the following videos:

OTDR Folder Instructions - nbn FTTC & FTTP
OTDR Set Up for NBN FTTC (DPU to FJL)
OTDR Training - Selecting the correct Pulse Width Setting for the MTM LFN

The OTDR Training video series is our way of continuing our commitment to providing the very best in technical support for our valued customers.



Video Series  Inspect Before You Connect ™ Training Videos
Inspect Before You Connect ™ Training Videos

This Video Series currently contains the following training videos:

⟹ Inspect Before You Connect Introduction
⟹ Proactive vs. Reactive Inspection
⟹ Importance of Inspecting BOTH Sides of a Connection
⟹ The Importance of Inspecting New Fibre Connectors
⟹ Cleaning Stick vs. a Clicker
⟹ Static Charge and Contamination
⟹ Understanding Fibre Cleaning Solvents
⟹ The Importance of Reliable Cleaning Tools
⟹ Understanding the IEC-61300-3-35 Standard
⟹ The Importance of Automated Pass/Fail Analysis for Fibre Inspection
⟹ The Importance of Documenting Fibre Inspection Results
⟹ The Importance of Investing in Inspection and Cleaning Today

These videos are presented by Tyler Vander Ploeg (VIAVI Solutions) and Brian Teague (MicroCare)


Back to Top

Glossary

BJL Breakout Joint
CSP Content Service Provider
DDD Detailed Design Documentation
DFN Distribution Fibre Network
FAN Fibre Access Node
FDH Fibre Distribution Hub
FJL Flexible Joint Location
FTTN Fibre to the Node
FTTB Fibre to the Building
FTTC Fibre to the Curb
HFOC Hardened Fibre Optic Connector
IOR Index of Refraction
LFN Local Fibre Network
MDU Multi-Dwelling Unit
MFD Mode Field Diameter
MPT Multiport
MT-DFN Multi-Technology – Distribution Fibre Network
MT-LFN Multi-Technology – Local Fibre Network
MT-DFN/LFN Multi-Technology – Distribution Fibre Network/Local Fibre Network
MTM Multi-Technology Mix
OTDR Optical Time Domain Reflectometer
PCD Premises Connection Device
PON Passive Optical Network
[Fibre-to-the-Curb-FTTC]
VIAVI P5000i FBP-MTS-101 W/FiberCheckPro, 7 Inspection tips, case
VIAVI Solutions logo

VIAVI P5000i FBP-MTS-101 W/FiberCheckPro, 7 Inspection tips, case

Sumitomo TYPE-72C-KIT High Definition Core Aligning Fusion Splicer
Sumitomo logo

Sumitomo TYPE-72C-KIT High Definition Core Aligning Fusion Splicer

Sumitomo TYPE-71M-KIT Mass Ribbon Fusion Splicer
Sumitomo logo

Sumitomo TYPE-71M-KIT Mass Ribbon Fusion Splicer

Exec Time: 0.062699 Seconds Memory Usage: 4.319221 Megabytes